CHAPTER 4 Installation of Operating System and bundled software
4.7 Procedure to install VMware 5.x on the SAN storage device
See
"3.4.5 Various mode
5.
Connect only the LUN which installs the SAN storage device to the partition of PRIMEQUEST.
For the setting of SAN storage device, see the manual attached with the SAN storage device.
6.
Allocate the I/O space in the FC card for boot path and in the SAS RAID controllerRAID card.
For details on allocation of the I/O space, see
Assignment] menu" of PRIMEQUEST 2000 Series Tool Reference (CA92344-0539).
7.
Set PCI Address Mode to PCI Bus Mode by MMB Web-UI.
For details on PCI Address Mode setting, see "1.3.8 [Partition#x] Menu" of PRIMEQUEST 2000 series Tool
Reference Manual (CA92344-0539).

4.7.2 Preparation of installation

Additionally, see the VMware information, at the time of preparation of the installation.
For the VMware information, contact the distributor where you purchased your product, or your sales representative.
The following preparation is done just before the installation.
1.
The following disk image is prepared.
Media of VMware 5.x
2.
The FC cable is made a single path (wire connection of only 1 FC cable).

4.7.3 Installation of VMware 5.x

The operating system installation with SVIM is explained.
There are the following types for operating system installation with SVIM. For the detailed procedure of each mode, see
ServerView Suite ServerView Installation Manager.
Mode
Functional Overview
Quick mode
You can simply use the minimum settings necessary for
operating system installation. This mode uses Fujitsu's
recommended settings.
Guide mode
You can specify setup information by following the instructions
of the wizard. You can save the specified information in a
configuration file for use during reinstallation.
All the screenshots are display examples. The contents displayed may differ depending on system configuration.
Operations
1.
The settings are done to boot the ServerView Suite DVD from virtual media for the partition.
For details on configuration, see"1.6.2 Remote control operation (BMC)" of PRIMEQUEST 2000 series
Administration Manual (CA92344-0537).
2.
The power supply of the partition is turned ON.
Note:
It can be started by selecting "Force boot from DVD" by Boot Selector or it can be started from the virtual media by
changing the boot order to DVD by UEFI.
When the operating system is applicable for UEFI mode, the installation can be done in UEFI mode by changing the
boot order according to the following procedure.
a.
After turning on the power supply of the partition, while the FUJITSU logo is displayed, press any key (such as
[Space] key) except [Enter] key and the Boot Manager front page is displayed.
b.
The menu is selected on the Boot Manager front page in the following order. [Boot Maintenance Manager]-
[Boot Options]-[Change Boot Order]-[Change the order]
c.
For UEFI aware OS, UEFI: Fujitsu Virtual CDROMx xxx is set at the upper-most step.
For Legacy OS, Fujitsu Virtual CDROMx xxx is set at the upper-most step.
For details on the setting method of boot order, see "■ Change Boot Order of "3.5.2 [Boot Options] menu" of
settings"
"3.4.5 Various mode
Operating system installation with SVIM
TABLE 4.5
settings" and "5.5.1 [Configure I/O Space
Purpose
For easy installation.
For detailed setting of RAID or OS.
77
CA92344-0536-01