CHAPTER 3 Work before Operating System Installation
3.4 Partition Configuration (Physical Partition)
Points to be considered for VMware
When switched to Reserved SB by the partition wherein ESX is in operation, the guest operating system may not be
activated at the time of the initial start after switching to the Reserved SB.
Set the items of automatic activation of guest operating system and BlueScreenTimeout while configuring the Reserved SB
in the partition wherein ESX is in operation.
For example, to reset the items 20 seconds after a panic occurs in the ESX host, set "20" to BlueScreenTimeout.
Remark
If items are not reset, when ESX host becomes panic, set "0" to BlueScreenTimeout.
Setting method of BlueScreenTimeout
Execute BlueScreenTimeout settings from vSphere Client.
1.
[Configuration] tab of host is opened on vSphere Client. Click [Detailed settings] of [Software] column.
2.
[Detailed settings] window is opened. Click [Misc] in left side column.
3.
Each parameter is displayed in right side frame. BlueScreenTimeout value is set to [Misc. BlueScreenTimeout].
Settings of BlueScreenTimeout ([Configuration] tab)
FIGURE 3.24