ALL MEASUREMENTS GIVEN ARE FROM THE CENTER LINE OF VENT CAP
∨ -
Vent Terminal
A =
Clearance above grade, veranda, porch, deck, or
balcony (*12 inches (30 cm) minimum). Vinyl sur-
faces require 24" min.
B =
Clearance to window or door that may be opened
(*12 inches (30 cm) minimum.
C =
Clearance to permanently closed window (mini-
mum 12 inches (30 cm).
D =
Vertical clearance to ventilated soffit located
above the terminal from the center-line of the ter-
minal (12 inches (30 cm) minimum) Vinyl surfaces
require 24" min.
E =
Clearance to unventilated soffit (18 inches (46 cm)
minimum) Vinyl surfaces require 24" min.
F =
Clearance to outside corner - 6 inches (15 cm).
G =
Clearance to inside corner - 12 inches (30 cm).
Vinyl surfaces require 24" min.
† A vent shall not terminate directly above a sidewalk or paved driveway, which is located between two single-family
dwellings and serves both dwellings.
‡ Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* As specified in CGA B1:19 Installation Codes (1991). Note: Local codes or regulations may require different clearanc-
es.

EXTERIOR VENT LOCATIONS AND RESTRICTIONS

Figure 2: Exterior Vent Locations
∧ -
Air Supply Inlet
H =
I =
J =
K =
L =
M =
N=
≡ -
Area where terminal is not permitted
*Not to be installed above a meter/regulator assembly
within 3 feet (90 cm) horizontally from the center-line of
the regulator
Clearance to service regulator vent outlet (*6 feet (1.8m)
minimum)
Clearance to non-mechanical air supply inlet to building
or the combustion air inlet to any other appliance.
*12 inches (30 cm) minimum.
Clearance to a mechanical air supply inlet (*6 feet (1.8
m) minimum)
† Clearance above paved side-walk or a paved driveway
located on public property (*7 feet (2.1 m) minimum)
Clearance under veranda, porch, deck, or balcony (*18
inches (30 cm) minimum ‡)
Minimum 24" horizontal clearance to any surface, such
as an exterior surface, for vertical terminations.