Specifications; Minimum Clearances From Combustible Construction; Building Permit And Installation Inspection Approval Requirements - Mendota DXV35 DT4-LX Installation & Operating Instructions Manual

Gas direct vent fireplace with premium texture fiber logs combustion system
Table of Contents

Advertisement

INPUT RATES (Btu/Hr)
NAT. GAS
LP GAS
NOTE: LP CONVERSION KIT #HA-30-00501 MUST BE PURCHASED SEPARATELY TO BURN LPG.
MAIN ORIFICES...
REAR BURNER
OVERALL EFFICIENCY
CO-AXIAL DIRECT VENT FLUE .... Top Vent: 4" Inner, 6 5/8" Outer
APPROVED VENT SYSTEMS: Amerivent, Duravent, Selkirk Metalbestos, Security Chimney and ICC
NET WEIGHT ................................... 185 POUNDS
SAFETY ........................................... AGA CERTIFIED PILOT GENERATOR, MILLIVOLT SYSTEM
GAS REQUIREMENTS .................... SUPPLY PRESSURE:
ELECTRICAL REQUIREMENTS..... 115 VOLT, LESS THAN 2 amps, Un-switched direct power.
f i r e - p a r t s . c o m
Unit to floor
Unit to enclosure sidewall
Vent to enclosed
Vent to adjacent sidewall
Certified under ANSI Z21.88 (2005)
Approved or bedroom installations and mobile homes. UL307B approved for "mobile homes, after first sale of
home, not for recreational vehicles."
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American
National Standards Institute - ANSI Gas Appliance Safety Standards. The Mendota Gas DXV Fireplace has been tested
and certified by Intertek Testing Services 8431 Murphy Drive, Middleton, WI
Fireplace Includes A Sealed Combustion System, 9-Piece Ceramic Fiber Log Set & Coals, Firebrick Lined Firebox, Neo-
Ceram Glass, Piezo Igniter, Dual Blowers, Aga Certified Safety System, and Smart Thermostatic Remote Control.
Options: Black, Brass, Classic Brass Or Classic Silver Tone Grill Sets, Black Or 24k Gold "Victoria" & "Tuscany" Filigree
Fronts, Bentley Arched Doors, Andover Arched Doors & 4 Color Overlay Fronts, Prairie Rectangular Doors & 4 Color
Overlay Fronts, Deerfield Front, Wellington Front, Versiheat Remote Forced Air Heat Transfer System, Versiheat II Forced
Air Heat Transfer System, Thermostats.

Building Permit and Installation Inspection Approval Requirements

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER.
High Fire -
33,000
33,000
: #44 NAT. GAS [3/64" L.P. GAS] –
Exceeds D.O.E. Efficiency Requirements (A.F.U.E.) For Direct Vent Wall Heaters.
78.5% Steady State Efficiency
ACTIVATED WITH REMOTE CONTROL.
NAT. GAS:
L.P. GAS:

MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION

0 in.
0.5 in.
1 in.
10 in.
CSA 2-33 (2005) "Vented Gas Fireplace Heaters" not for use with solid fuel.
All installations of Mendota Fireplaces and Inserts must comply with all
the requirements stated in this Installation and Operating Instructions
Manual. The Dealer and/or installer must also obtain all required Building
Permits and Inspection Approval from the local building inspection de-
partment or the local body having jurisdiction. In order to validate warran-
ty coverage, Mendota may require facsimile copies of the Building Permit
and Inspection Approval forms. Failure to provide adequate proof that
the installation conforms to all local requirements and the requirements
stated in the Installation and Operating Instructions Manual will void all
applicable warranty.

SPECIFICATIONS

MODEL DXV-35 DT4
Adjustable to -
FRONT BURNER
GAS INLET: 3/8" N.P.T.at Gas Valve Entry Point
7" W.C. (5" W.C. MIN., 11" W.C. MAX.)
12.0" W.C. (12" W.C. MIN., 14" W.C. MAX.)
Unit to enclosure sidewalls
Unit top to ceiling
Wall Pass-Through to framing
Mantle above discharge air opening
5
Low Fire
10,000
13,000
: #49 NAT. [3/64" LP]
0.5 in.
18 in.
1 in.
14 in.