Managing an ICX 6430 or ICX 6450 device

This chapter contains the following sections:
DANGER
The procedures in this manual are for qualified service personnel.

Managing temperature settings

The device contains temperature sensors that the software reads based on a configurable device
poll time. Except for the ICX 6430-24 model, the device has two automatic speed fan control
settings based on the temperature. To protect the device from overheating, the following
temperature threshold levels exist:
TABLE 16
Model
ICX 6430
ICX 6450

Displaying the temperature

To display the temperature of a device, enter the show chassis command at any level of the CLI.
The show chassis command displays the power supply status, and temperature threshold levels for
fan speed.
Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide
53-1002738-02
Managing temperature settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Displaying CPU usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Removing MAC address entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
The warning level is the temperature at which the device generates a syslog message. It is
configurable up to
.
83°C
The shutdown level is the temperature at which the device reboots. It is set by the device and is
not configurable. When the device temperature reaches the shutdown level, it generates a
warning message that the device's temperature is over the shutdown level and the device will
shutdown in five minutes. The system restarts five minutes after the device reaches the
temperature shutdown level.
Temperature thresholds
Warning level temperature threshold
(
°C)
Brocade recommends setting the
warning level temperature no higher
than 83°C.
Critical (shutdown) temperature
threshold
(
°C)
88°C