5
Managing temperature settings
NOTE
The displayed temperature reflects the temperature of the board inside the device.
Brocade# show chassis
The stack unit 1 chassis info:
Power supply present, status ok
Fanless model
Sensor B Temperature Readings:
Sensor A Temperature Readings:
Boot Prom MAC : 748e.f8ea.0360
Management MAC: 748e.f8ea.0360
=====
Syntax: show chassisshow chassis
Displaying syslog messages for temperature
The software sends a syslog message and an SNMP trap if the temperature crosses the warning or
shutdown thresholds. The following method describes how to view the system log on the device. If
you have configured the device to use a syslog server or SNMP trap receiver, refer to the
documentation for the server or receiver.
To display the system log, enter the show log command at any CLI level.
68
Current temperature : 55.0 deg-C
Current temperature : 50.0 deg-C
Warning level.......: 76.0 deg-C
Shutdown level......: 83.0 deg-C
Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide
53-1002738-02