Managing an ICX 6430 or ICX 6450 device

Managing temperature settings.......................................................................................77

Displaying CPU usage.................................................................................................... 80
Removing MAC address entries..................................................................................... 80
DANGER
The procedures in this manual are for qualified service personnel.
Managing temperature settings
The device contains temperature sensors that the software reads based on a configurable device poll
time. Except for the ICX 6430-24P model, the device has two automatic speed fan control settings
based on the temperature. To protect the device from overheating, the following temperature threshold
levels exist:
The warning level is the temperature at which the device generates a syslog message. It is
configurable up to 83°C.
The shutdown level is the temperature at which the device reboots. It is set by the device and is not
configurable. When the device temperature reaches the shutdown level, it generates a warning
message that the device's temperature is over the shutdown level and the device will shutdown in
five minutes. The system restarts five minutes after the device reaches the temperature shutdown
level.
TABLE 15
Model
ICX 6430
ICX 6450

Displaying the temperature

To display the temperature of a device, enter the show chassis command at any level of the CLI. The
show chassis command displays the power supply status, and temperature threshold levels for fan
speed.
NOTE
The displayed temperature reflects the temperature of the board inside the device.
Brocade# show chassis
Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide
53-1003079-01
Temperature thresholds
Warning level temperature threshold
(°C)
Brocade recommends setting the warning level temperature
no higher than 83°C.
Critical (shutdown) temperature
threshold
(°C)
88°C
77