InfiniBand Switch Platform Hardware User Manual
Table 10 - LEDs Display for Normal Operation
LED Condition
STATUS
PSU STATUS
SPINE FANS
STATUS
LEAF FANS
STATUS
MNG1
MASTER
STATUS
MNG2
MASTER
STATUS
Mellanox Technologies

Figure 49: Spine Side Panel Display Status Indications

Off – No Power
Green – System is up and running
Yellow – System warning. Attention needed (such as overheating)
Red – System not operational (Diagnostics fail, CPU hang,
HW fail, Overheat-critical)
Blinking green – System booting / Restore factory defaults in progress
Off – No power
Green –Normal operational
Red – PS fault detected. User should check individual power supplies
for fault indications.
Off – No power to fan
Green – Nominal operational
Red – One or more of the spine fans is bad. User should check
individual spine fan LEDs for fault indications.
Off – No power to fan
Green – Nominal operational
Red – One or more of the leaf fans is bad. User should check
individual leaf fan LEDs for fault indications.
Off –
- no power
- this management module is not installed
- this management module is not the master
Green – Management module is operating as a master
Off –
- no power
- this management module is not installed
- this management module is not the master
Green – Management module is operating as a master
Description
Normal
State
Green
Green
Green
Green
Green
Off