Table 8.12. Error Codes. Suggested Actions - Tandberg Data StorageLoader Installation And User Manual

Hide thumbs Also See for StorageLoader:
Table of Contents

Advertisement

1209
Failed to fetch
at slot 09
2000
Drive not
found
2001
Drive
hardware fault
detected.

Table 8.12. Error Codes. Suggested Actions.

73
StorageLoader Installation and User Manual
Failed to eject
1. Reboot the loader and retry the
cartridge from
operation.
drive
2. Try to eject the cartridge from
the drive via the front panel menu.
3. Remove the drive FRU.
Connect power to drive and push
the drive's eject button. If this
fails, remove cartridge by
following the drive's emergency
eject procedure.
Communication
1. Reboot the loader and retry the
error between
operation.
the loader and
2. Remove back-panel cover plate
the drive.
and check the SCSI cabling and
the ADI cabling.
The drive has
Reboot the loader and retry the
reported a
operation. If the problem persists
hardware fault.
replace the drive.
Defect drive or
robotics. Defect
cartridge.
SCSI and signal
cables, power
cables; defective
power supply;
defective drive.
Defective drive