3.1.5.5 PIPE CONNECTOR AND DAMPER
The Caddy wood Add-on furnace must be connected to a duct system and a
chimney that are in good condition; even if it is allowed, the use of separate
chimneys is recommended.
If the furnace is connected to an oil furnace and both appliances must share the
same chimney, the chimney and smoke connector must be 7" in diameter and
approved for use with wood-burning appliances. The use of 6" connector and
chimney is permitted if the wood furnace evacuates into a separate chimney. It's
strictly forbidden to connect a solid fuel burning appliance to a chimney
already connected to a propane or natural gas appliance. Regulation CAN-
CSA-B365.1.
WARNING
DO NOT INSTALL A MANUAL DAMPER.
OIL PIPE
REDUCER
7" DIAMETER
3.1.6 ELECTRICAL CONNECTIONS
The following instructions do not replace those of the local code.
Installation and verification of this appliance must be done by a qualified
service man.
All wiring from the service panel to the heating unit must comply with the
electrical code in force and all local regulations. It is recommended to feed the
furnace with its own electrical circuit of 15 amps at 120 volts with a breaker (see
wiring diagram).
28