Thermostat Installation - PSG Caddy PF01010 Installation And Operating Instructions Manual

Table of Contents

Advertisement

SERVOMOTOR
Plastic grummets are installed on the upper edge of the blower box through
which the blower cable (prewired 14-3 BX) will run before reaching the junction
box located next to the blower where it will be connected.
The low voltage control circuit will be fed from the transformer attached to the
junction box of the fan limit assembly and the 120 volts circuit from the house
electrical entrance will also be connected to that junction box as per the wiring
diagram

3.2.3.3 THERMOSTAT INSTALLATION

The thermostat must be installed on an inside wall in a location where it is not
likely to be affected by the draft coming from an air outlet. It must be installed at
a minimum of 55 inches above the floor
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents