22.4. FLOOR PROTECTION

See Section 9.7.4 - FLOOR PROTECTION

22.5. HOT AIR PLENUM

See Section 9.12 - HOT AIR PLENUM

22.6. CONNECTING PIPE AND MANUAL DAMPER

The pipe connecting the furnace to the chimney must be as short and as straight as possible. If a deviation is required,
o
the use of 45
elbows is highly recommended for a better evacuation of the smoke in the chimney of the wood burning
furnace. The barometric damper provided with the appliance must be installed on the oil unit evacuation pipe,
approximately 24" from the flue outlet of the unit.
TYPE OF FURNACE
MAX CADDY
54
MIMINUM CLEARANCES
A
24" (610 mm)
B
18" (457 mm)
C
6" (152 mm)
D
1" (25 mm)
E
72" (1829 mm)
F
24" (610 mm)
-1-
HEAT SHIELD
OIL BURNING UNIT FLUE
PIPE DIAMETER
G
8" (203 mm)
H
1.5" (mm)
I
24" (610mm)
J
24" (610mm)
K
9" (229mm)
5"