THE ELECTRICAL CURRENT FLOWING THROUGH THE BLOWER MOTOR
SHALL NOT EXCEED THE NAMEPLATE RATING.

3.1.5 APPLIANCE INSTALLATION

If the exiting furnace must be modified, the following standards mist be
respected:
Wood-oil
 NFPA 31: Standard for the installation of oil-burning equipment.
 CSA B.139: Installation code for oil-burning equipment.
Annexe Bois-gaz
 CSA B.139 : Installation code for oil-burning equipment.
 CAN/CGA-B149.1 & CAN/CGA-B149.2 : Natural Gas & Propane
Installation Code et Propane Storage & Handling Code.

3.1.5.1 UNIT LOCATION

The furnace must be installed where outside air supply will be sufficient for
proper combustion. In airtight houses, it might be necessary to install an outside
air inlet (see la Section 2.12, Fresh air intake.)
The furnace must be positioned so that the connector is as short as possible.
Minimize the use of 90
The owner must ensure a proper installation to allow a safe operation of
the appliance.
WARNING
o
elbows.