3.3.4.6 TECHNICAL DATA – ELECTRIC MODE
TEMP.
OUTPUT
MODEL
VAR.
(CFM)
(OF)
950
50
15 KW
1300
36
950
60
18 KW
1300
44
950
67
20 KW
1300
49
950
83
25 KW
1300
61
1800
44
WOOD

3.3.5 OPERATING INSTRUCTIONS

3.3.5.1 FAN LIMIT CONTROL

The fan limit control settings may need to be adjusted depending on the
installation, but they are set at 110 °F (fan OFF) and 150 °F. (Fan ON) at the
factory and these settings will work best in most installations.
For continuous operation of the blower, use the switch located below the fan limit
control which controls the low speed either at the "ON" position or the "OFF"
position.
It is not recommended to let the blower run on continuous mode when heating
with wood since the wood furnace must reach a certain temperature before the
blower starts in order to operate efficiently.

3.3.6 TECHNICAL DATA

See Section 3.2.5, in Caddy wood only furnace.
TOTAL
BTU/H
AMPERAGE
BREAKER
51195
75
100
61434
87
125
68260
95
125
85325
115
150
15
63
ALIMENT.
VOLTAGE
ÉLÉMENTS
CALIBRE
1 PHASE
4
120/240
3 – 5 KW
2 – 5 KW, 2 –
4
120/240
4 KW
3
120/240
4 – 5 KW
2
120/240
5 – 5 KW
120
# OF