3.4.3.3 BURNER PUMP

When the tank is located below the unit, the basic single course pump, powered
by a single duct, can compensate for a drop of 8 feet (244 cm) measured
between tank outlet and the height of entry into the burner.
When the rise is more than 8 feet (244 cm) and not exceeding 10 feet (305 cm),
a by-pass plug (provided with the burner) must be inserted in the pump and an oil
return pipe must be installed.
For more details, see "INSTALLATION
INFORMATIONS", Part No. 21844 on the burner pump.
If the rise is higher than 10 feet (305 cm), a two stage pump may be required
along with an oil return pipe.

3.4.4 APPLIANCE INSTALLATION

3.4.4.1 UNIT LOCATION

The furnace must be installed where outside air supply will be sufficient for
proper combustion. In airtight houses, it might be necessary to install an outside
air inlet (see details in Section 2.12.)
The furnace must be positioned so that the connector is as short as possible.
o
Minimize the use of 90
elbows.
The owner must ensure a proper installation to allow a safe operation of
the appliance.
Allow enough space for easy cleaning of the furnace and replacement of filters,
blower, motors, controls and pipe fittings.

3.4.4.2 PARALLEL INSTALLATION

See Section 3.2.2.2, in Caddy wood only furnace.

3.4.4.3 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

N.B.: THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE
INSTRUCTIONS ON THE CERTIFICATION PLATE APPLIED ON THE UNIT.
The floor on which the furnace is installed may be combustible. On a
combustible floor, use a protective plate exceeding 8 inches on each side
of the unit, 16 inches from the front of the door in the United States and 18
inches from the front of the door in Canada is required.