Lamp: Installation And Replacement - Coemar CF 1200 Hard Edge Instruction Manual

Hide thumbs Also See for CF 1200 Hard Edge:
Table of Contents

Advertisement

4. Lamp: Installation
and replacement
CF 1200 Hard Edge utilises a Philips MSR 1200 SA lamp of 1200W with
a GY 22 base.
The lamp is available from your authorised coemar sales agent:
coemar cod.
wattage
luminous flux
colour temperature
base
approximate life
Turn off the power prior to opening up the unit.
The fixture's internal temperature can reach 250° C after 5 minutes, with a maximum
peak of 350° C; ensure that the lamp is cold prior to attempting removal. The fixture
should be allowed to stand and cool for 10 minutes prior to its removal.
MSR/SA lamps are part of the mercury vapour family of discharge lamps and must be
handled with great care. The lamp operates at hight pressure, and the slight risk of
explosion of the lamp exists if operated over its recommended life of 500 hours.
We recommend, therefore, that the lamp be replaced within the manufacturer's spe-
cified lamp life.
mounting the lamp
1) Using a 3mm hex (Allen) key, remove the two hex bolts (A) which affix the lamp
assembly to the rear of the projector.
2) Remove the lamp assembly (B).
3) Locate the lampholder (C)
105090/1
1200 w
96.000 lm
6500° K
GY 22
500 hours
Attention

Advertisement

Table of Contents
loading