Configuring Call Properties; General Settings - RADVision Scopia XT1000 Administrator's Manual

Hide thumbs Also See for Scopia XT1000:
Table of Contents

Advertisement

Configuring Call Properties

When configuring the settings the system will use for in call transmission, take into account the
remote terminal capabilities.

General Settings

Procedure
Step 1
In the Administrator settings menu select Calls.
Step 2
Scroll to Preferences.
Step 3
Select the General page.
Step 4
Set the fields as required.
Note:
Field Name
Rate K (IP)
Audio Coding (IP)
Video Coding (IP)
Rate K (ISDN)
Step 5
Press
RADVISION | Administrator Guide for SCOPIA XT1000 Version 2.0
The default <auto> setting indicates that the system will always try to choose the best
option for the local situation.
Description
Sets the maximum call rate that the system will use for all
incoming or outgoing calls.
Sets the preferred Audio Coding that the system will try to use
for all incoming or outgoing calls, if the remote system supports
the same Audio Coding.
Sets the preferred Video Coding that the system will try to use
for all incoming or outgoing calls, if the remote system supports
the same Video Coding.
Sets the maximum call rate that the system will use for all
incoming or outgoing calls in ISDN connectivity . For ISDN
configuration, see
Save.
Configuring ISDN Connectivity page
46.
'Initial Configuration' | 49