CHAPTER 4 Installing the Operating System and Bundled Software
2. Change FC cabling to single path (connecting only one FC cable).
4.6.3

Installing VMware 4.x

Install VMware 4.x by following the instructions in the VMware vSphere Software Handbook.
For details on this handbook, contract your sales representative.
Before starting installation, see
4.6.4

Installing bundled software

After completing installation of the operating system, configure the bundled software.
- Installing ServerView Agent
(See
E.3.1 Installing ServerView
- Installing ServerView RAID
(See
E.3.2 Installing ServerView
- Installing RAS Support Service
(See
E.3.3 Installing RAS Support Service
- Installing HRM/server
(See
E.3.4 Installing VMware 4.x HRM/server
- Installing PSA (1800E)
(See
E.3.5 Installing VMware 4.x
- Installing SVmco (1800E2)
(See the ServerView Mission Critical Option User Manual)
4.6.5

Configuring bundled software

Configure the bundled software. For details on confirming and configuring the LAN, see
network.
1. Confirm the PSA-to-MMB communication LAN and management LAN.
The PSA-to-MMB communication LAN uses the physical adapter assigned BUS number 0000:00:19.0. The
management LAN uses an arbitrary physical adapter.
Execute the esxcfg-nics command to confirm the physical adapters used for the PSA-to-MMB
communication LAN and management LAN.
2. Configure the management LAN.
1. Use vswif0, which exists by default immediately after the installation of the operating system, for the
interface of the management LAN.
2. Execute the esxcfg-vswif command to assign an IP address to vswif0.
3. Configure the PSA-to-MMB communication LAN.
1. Execute the esxcfg-vswitch command to create a virtual switch (vSwitch1).
2. Execute the esxcfg-vswitch command to connect physical adapter vmnic0 to the virtual switch.
3. Add a port group (PSA-MMB) to the created switch.
4. Execute the esxcfg-vswif command to create a virtual port (vswif1).
5. Add the following settings to the PSA-to-MMB communication LAN:
Speed: 100 Mbps
Duplex: full
E.2 Notes on VMware 4.x