Initializing Mmb Settings - Fujitsu PRIMEQUEST 1000 Series Installation Manual

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series Installation Manual
CHAPTER 3 Work before Operating System Installation
Setting item
Data bit
Parity
Stop bit
Flow control
Emulation
3.3.2

Initializing MMB settings

The procedure for initializing MMB settings is as follows.
If the field engineer has already made the settings, you can skip the following procedure.
Operations
1. Power on the main unit.
>> The Alarm LED of each unit goes on while the MMB Ready LED is blinking (initialization in progress).
The login prompt appears.
2. Log in with Administrator privileges using the terminal software from the MMB console PC.
>> When you first log in, you will be asked to change the Administrator password.
3. Set a password.
Note
You need to set a hard-to-guess password consisting of at least eight characters.
If you enter an inappropriate password, you will be asked to enter another password.
4. Configure the MMB network.
Execute the command shown below to set the IP address.
Administrator> set ip <IPAddress> <netmask>
Administrator> set gateway<default gateway IP Address>
Example: The IP address is 192.168.0.10, netmask is255.255.255.0, and gateway is 192.168.0.1.
Administrator> set ip 192.168.0.10 255.255.255.0
Administrator> set gateway 192.168.0.1
5. Execute the set http enable command to enable http.
>> The MMB Web-UI is accessible from the MMB console PC via the LAN.
Administrator> set http enable
Remarks
To enable https, use the set https command.
Administrator> set http enable
Value
8
None
1
None
VT100
22
C122-E107-09EN