CHAPTER 4 Installing the Operating System and Bundled Software
Remark
The IP address of the LAN cannot be set through the operating system setup. Set the IP address after the
installation of the operating system.
7. Click [Install].
Installation begins.
8. Replace the media with the operating system installation media according to the SVIM instructions.
4.3.4

Configuring bundled software after the completion of installation

After completing OS installation, configure the bundled software.
1. Confirm that the PSA management LAN IP address is not the same as the IP address used for the production
network or management network. For details in the case of the PRIMEQUEST 1800E2, see the ServerView
Mission Critical Option User Manual. For details in the case of the PRIMEQUEST 1800E, see
Configuring the PSA-to-MMB communication
Remarks
The PSA management LAN is automatically assigned an IP address. Confirm that the IP address is not the
same as the IP address used for the production network or management network. If the IP addresses match,
change the PSA management LAN IP address. Also, if the subnets match, change the subnet setting on the
MMB side.
2. Configure and confirm the management LAN.
- Configuring the management LAN used for communication with the MMB
(See
6.2.2 Confirming management LAN
If necessary, configure any duplication with bonding or PRIMECLUSTER GLS, for example.
- Confirming SELinux function settings
(See
6.2.3 Confirming SELinux function
Confirm that the SELinux function is [disabled].
3. Check the firewall function. For details, see
- Open the ports for the PSA-to-MMB communication LAN interfaces.
snmp port: udp/snmp or 161
web-mmb communication port: tcp/fj-webgate or 24450
psa-mmb communication port: tcp/5000 on the MMB side
icmp: echo-request
icmp: echo-reply
4. Set the destinations of SNMP trap from the partition.
Set the destinations of traps and PSA trap notification on the partition side as needed. For details, see
Setting the destinations of traps from a
Remarks
LAN.
settings.)
settings.)
6.2.4 Checking the firewall function (opening
partition.
70
6.2.1
ports).
6.2.5
C122-E107-09EN