Ventilation and Spacing

DO NOT place the scanner in a close-fitting, fully enclosed checkstand. Pro-
vide a MINIMUM of 16 square inches (103.2 square centimeters) of air intake
from below the installation for sufficient convective cooling.
NOTE
Product Reference Guide
Should such an enclosure be unavoidable, an alternate method of platter
removal using two coins may be employed, however a minimum vertical
clearance of 1.5" (3.8 cm) MUST be provided (reference
Another consideration is that the scan zone must be kept free of obstruc-
tions such as enclosures, keyboard mounts, etc.
Figure 2-2. Vertical Clearance
DO NOT
Obstruct
L-Platter
Removal
Allow a minimum
clearance of
1.5" (3.8cm)
(Enclosure)
The scanning-scale's perimeter housing has been designed to provide ade-
quate space for convective cooling and unrestricted movement of the
weighing apparatus.
Figure 2-3
slots. The checkstand design must allow:
The ambient air temperature inside the checkstand adjacent to
the scanner must not exceed 104°F (40°C).
A source of air that provides adequate cooling by convective air
flow.
shows the debris chutes and ventilation
).
Figure 2-2
DO NOT
Obstruct
Scan Zone
2-7