Datalogic Magellan 8500Xt Product Reference Manual page 111

Hide thumbs Also See for Magellan 8500Xt:
Table of Contents

Advertisement

Shift Test
(Models vary)
Product Reference Guide
The Shift Test checks to ensure that items placed anywhere on the weigh-
ing surface of the scanner/scale are weighed properly. Refer to
when performing this test.
1. Place and remove in succession, a ten-pound load on the center of
each of the four quadrants (1, 2, 3, and 4 in Figure 5-2) of the
scanner/scale's weigh platter. Verify that a reading of between 9.99
and 10.01 lb registers under load and that the display returns to
0.00 between each load.
2. After verifying the accuracy of each quadrant of the weighing sur-
face, remove all weight from the scale. You have completed the
Shift Test.
Figure 5-2. Shift Test