Code 39 Length 2 - Datalogic Magellan 8500Xt Product Reference Manual

Hide thumbs Also See for Magellan 8500Xt:
Table of Contents

Advertisement

Code 39 Length 2

NOTE
7-212
If Code 39 Length Control is set to Fixed-Length decoding, this feature
specifies Code 39 second fixed length. If Code 39 Length Control is set to
Variable-Length decoding, this feature specifies the maximum label
length.
When in Fixed Length mode, if Length 2 is set to the value of 00, then
only Length 1 will apply
To set this feature:
1. Scan the SWITCH barcode.
2. Scan the barcode, SET CODE 39 LENGTH 2 below. You'll need
to cover any unused barcodes on this and the facing page to
ensure that the scanner reads only the barcode you intend to scan.
3. Scan the appropriate digits from the keypad in
represent the desired label length. The selectable range for this
option is 00, no second fixed length, or 01 to 50. Pad all single
digit numbers with a leading zero to yield a two-digit entry (00-
50).
4. Complete the programming sequence by scanning the SWITCH
barcode.
SET CODE 39 LENGTH 2