3.7.6.8 Removing the Right Frame

1) Remove the 5 screws [1], and detach the right frame [2].
[2]

3.7.6.9 Removing the Shield Plate

1) Free the flat cable [1] from the connector.
2) Remove the 6 screws [2], and detach the shielding plate [3].
[2]

3.7.6.10 Removing the Fixing Motor

1) Unplug the 1 connector [1] and remove the 4 screws [2].
2) Remove the fixing motor [3] from main unit.
[1]
[2]
F-3-1093
[1]
[1]
F-3-1094
[3]
[1]
[2]
F-3-1095