[1]
Enlarged View of the Paper Retainer
OK
[3]
When attaching the top cover, be sure to fit the link lever [2] while keeping
the drive release lever [1] in up position (i.e., with drive disengaged).
If you are fitting the drum cartridge in the machine with the top cover re-
moved, be sure to do so with the drive release lever [1] fully in up position
(i.e., with drive disengaged).
If the drive release lever is in low position (i.e., with drive engaged), it forces
out the coupling [2], causing the coupling to interface with the drum car-
tridge and to suffer damage.
[2]
F-3-965
NG
[3]
F-3-966
[2]
[1]
F-3-967
3.6.9.10 Removing the Right Frame
1) Remove the 5 screws [1], and detach the right frame [2].
[2]
3.6.9.11 Removing the Left Frame
1) Remove the 4 screws [1], and detach the left frame [2].
[1]
3.6.9.12 Removing the Cassette Feeder
1) Lift the machine, and detach the cassette feeder [1].
Chapter 3
[1]
[2]
F-3-968
[1]
[1]
F-3-969
[2]
[1]
F-3-970
0011-6606
0007-8807
0007-8815