Chapter 10
[2]
[1]

10.4.4 Fixing Motor

10.4.4.1 Before Removing the Fixing Motor

MEMO:
26 parts (e.g.: external cover, unit) need to be removed when removing the
fixing motor. Be sure to have enough space equivalent to 1,900mm x
1,100mm for storing parts.
1100mm
1) Remove the ETB unit.(page 8-30)Reference [Removing the ETB Unit]
2) Remove the fixing assembly.(page 10-6)Reference [Removing the Fix-
ing Assembly]
3) Remove the rear cover unit.(page 11-11)Reference [Removing the Rear
10-12
[1]
[3]
F-10-39
Cover Unit]
4) Remove the ADF Unit + Reader Unit.(page 5-8)Reference [Removing
the ADF Unit + Reader Unit]
5) Remove the left cover.(page 11-13)Reference [Removing the Left Cov-
er]
6) Remove the right cover.(page 11-11)Reference [Removing the Right
Cover]
7) Remove the Upper Frame Unit.(page 11-18)Reference [Removing the
Upper Frame Unit]
8) Remove the Reversal Unit.(page 9-26)Reference [Removing the Re-
versal Unit]
9) Remove the Fixing Drive Unit.(page 10-9)Reference [Removing the
Fixing Drive Unit]

10.4.4.2 Removing the Fixing Motor

1) Disconnect the 3 connectors [1].
2) Remove the fixing driver PCB [1].
0018-9647
- 3 screws [2]
[2]
3) Free the harness [1] from the harness guide [2].
4) Remove the screw [3] to pull out the sensor and the attaching plate [4].
[1]
F-10-40
[1]
[2]
F-10-41
0018-9695