8.4 Parts Replacement Procedure

8.4.1 Fixing Unit

8.4.1.1 Removing the Fixing Unit

/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
The height of the fixing unit is adjusted at 2 mounting points at the front (left
door + front cover) prior to shipment. If you need to detach the fixing unit,
apply 2 markings [1] before detaching the unit to enable you to return the unit
to its previous position. When replacing the fixing unit with a new one, carry
out height adjustment.
1) Detach the rear cover, front cover, front-left cover, rear-left cover,
delivery tray fron cover and internal cover.
2) Remove the boss [1], and then slide the guide (front) [2] to remove it.
[1]
[1]
F-8-4
[1]
0013-1240
3) Disconnect the two connectors [1], and then release the cable from the
clamp.
[1]
4) Remove the screw [1] and remove the fan duct [2].
5) Remove the three connectors [3] and one screw [4], and then slide the fan
unit [5] upward to remove it.
6) Remove the boss [1], and then slide the guide (rear) [2] backward to
remove it.
Chapter 8
[2]
F-8-5
F-8-6
[1]
[2]
[5]
[3]
[4]
F-8-7