Removing The Right Frame; Removing The Shield Plate; Removing The Rotary Drive Assembly - Canon MF8100 Series Service Manual

Mf8100 series
Table of Contents

Advertisement

[1]
Enlarged View of the Paper Retainer
OK
[3]
When attaching the top cover, be sure to fit the link lever [2] while keeping
the drive release lever [1] in up position (i.e., with drive disengaged).
If you are fitting the drum cartridge in the machine with the top cover re-
moved, be sure to do so with the drive release lever [1] fully in up position
(i.e., with drive disengaged).
If the drive release lever is in low position (i.e., with drive engaged), it forces
out the coupling [2], causing the coupling to interface with the drum car-
tridge and to suffer damage.
[2]
F-3-799
NG
[3]
F-3-800
[2]
[1]
F-3-801

3.5.12.8 Removing the Right Frame

1) Remove the 5 screws [1], and detach the right frame [2].
[2]

3.5.12.9 Removing the Shield Plate

1) Free the flat cable [1] from the connector.
2) Remove the 6 screws [2], and detach the shielding plate [3].
[2]

3.5.12.10 Removing the Rotary Drive Assembly

1) Disconnect the 4 connectors [1], and remove the 2 screws [2].
Chapter 3
[1]
[2]
F-3-802
[1]
[1]
F-3-803
[3]
[1]
[2]
F-3-804
0011-6602
0011-6621
0007-8865
3-123