Figure 2-2 Installing Expansive Pipe; Figure 2-3 Fixing Cabinet With Tap - Emerson ACTURA Flex 48330 User Manual

Power system
Table of Contents

Advertisement

16
Chapter 2 Installation
not to shake the drill, and try to keep as vertical as possible to the ground, as
shown in Figure 2-2.
Step 3: install expansive pipes.
Clean the dust, and insert the expansive pipe into the reserve hole, knock it down
gently using a hammer until the top of the expansive pipe is level with the ground,
as shown in Figure 2-2.
Step 4: place cabinet in position
Move the cabinet to the installation position aligning the installation holes of the
cabinet to the expansive pipe on the ground.
Step 5: fix the cabinet
After the cabinet is in position, make some horizontal and vertical adjustments.
Insert some iron pieces under the lower edge and corner of the cabinet to adjust
the vertical obliquity of the cabinet within 5 degrees. Finally, screw down the tap
bolt with plain washer and spring washer into the expansive pipe, and tighten it with
wrench. The cabinet fixation is illustrated in Figure 2-3.
2) Clean the dust
1) Drill vertically

Figure 2-2 Installing expansive pipe

Spring washer

Figure 2-3 Fixing cabinet with Tap

ACTURA Flex 48330 Power System User Manual
Power
Expansive
cabinet
pipe
3) Knock it into place
Tap bolt
Plain washer
Cabinet base
Ground
Expansive pipe
4) Tighten the bolt

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents