Chapter 5 Operating SCU
Serial
Alarm
No.
14
Batt Temp Low
15
Amb Temp High
16
Amb Temp Low
17
No TempSensor1
18
No TempSensor2
TempSensor1
19
Err
20
TempSensor2 Err
21
LLVD
22
BLVD
23
Load 1 Faiure
24
Load 2 Faiure
25
Load 3 Faiure
26
Load 4 Faiure
27
Load 5 Faiure
28
Load 6 Faiure
29
Load 7 Faiure
30
Load 8 Faiure
31
Load 9 Faiure
32
Aux Load Fails
33
Batt1 Failure
34
Batt2 Failure
35
Batt3 Failure
Description
Battery temperature is lower than the
set value of parameter "Temp
Threshold: Low Temp"
Ambient temperature is higher than
the set alarm point
Ambient temperature is lower than
the alarm point
Temperature sensor 1 has been set,
but no sensor is actually connected
Temperature sensor 2 has been set,
but no sensor is actually connected
Temperature sensor 1 detected
unreasonable temperature
Temperature sensor 2 detected
unreasonable temperature
1. Load disconnection
2. Manual load disconnection
1. When battery discharges till its
voltage is lower than the "BLVD
Volt", or the discharge time is longer
than the "BLVD Time", the BLVD
contactor will be open automatically
2. BLVD through manual operation
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
The last route faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
Over-load, short circuit, manual
disconnection or alarm circuit faulty
ACTURA Flex 48330 Power System User Manual
Default
Default
related
alarm level
relay
Low temperature alarm
Observation
None
point
Observation
None
Observation
None
Critical
None
Critical
None
Critical
None
Critical
None
Critical
5
LLVD enabled
Critical
4
BLVD enabled
Critical
6
Critical
6
Critical
6
Critical
6
Critical
6
Critical
6
Critical
6
Critical
6
Critical
6
Critical
6
Critical
None
Critical
None
Critical
None
Related parameter
configuration