4. Keypad Panel

The keypad panel is provided with various
functions such as operation (frequency setting
and start/stop commands) from the keypad
panel, monitor and alteration of function code
data, and various confirmation functions.
Be familiar with the operation method of each
function before starting operation.
4-1

Appearance of Keypad Panel

(1) Monitor display mode
In the regular operation mode, press the
key
to switch between frequency
FUNC
DATA
display, output current display and other
display.
Output frequency *
1
6
0.
0
0
Synchronization
rotation speed *
2
1
0
0
0
*1: In the PID control mode (when function H20
is at "1" or "2"), the value is in the percent
display and the dot at the least significant
digit always lights up.
Example: 10%:
1
0.
0.
*2: Press the
,
V
these data to display the frequency setting.
4-1
Output current *
2
1.
2
0
Output voltage *
2
2
0
0
Line speed *
2
1
0
0
0
, 100%:
1
0
0.
0.
key during display of
➀ Digital display
Various function codes and data codes for
programming are shown.
The output frequency, output current and
other data are displayed during operation,
and the cause of a trouble is displayed
using codes when protective function
works.
➁ Program (PRG)/RESET key
Press this key to switch over between the
regular operation mode and programming
mode. Use this key to reset an alarm
stopping state after activation of a protective
function.
➂ Unit and operation mode display
The unit of the data displayed at the digital
display is indicated with an LED. The
program mode is indicated. The PANEL
CONTROL lamp lights up in the keypad
panel operation mode.
➃ RUN key
Press this key to start operation. An LED
lights up during operation. When data code
=
F
0
2
1
function.
➄ STOP key
Press this key to stop operation. When data
code
=
F
0
2
function.
➅ Up/down keys
Press these keys to increase or decrease
the frequency or speed.
In the programming mode, use these keys
to change the function code or data setting.
➆ Function/Data key
Use this key to switch over between
frequency display, output current display
and other display in the regular operation
mode. In the programming mode, use this
key to retrieve or write various function
codes and various function data.
, the key does not
, this key does not
1
Keypad Panel