P: Motor parameters
Name
P01
Number of motor 1
poles
P02
Motor1
(Capacity)
P03
(Rated current)
_ Tuning)
P04
P05
(Online tuning)
P06
(No-load current)
_ R1 setting _
P07
_ X setting _
P08
P09
(Slip compensation
control 1)
P10
(Slip compensation
response time 1)
Description of change during operation
: The data changed by the
effect on the inverter operation. However,
press the
key to store the new data.
FUNC
DATA
5-6
Setting range
2 to 14
0.01 to 5.5kW (4.0kW or less)
0.01 to 11.00kW(5.5/7.5kW)
0.00 to 99.9A
0: Inactive
1: Active (%R1, %X)
2: Active (%R1, %X, Io)
0: Inactive
1: Active
0.00 to 99.9A
0.00 to 50.00%
0.00 to 50.00%
0.00 to 15.00Hz
0.01 to 10.00s
or
key takes
V
Min.
Factory
unit
setting
2
Nominal
0.01kW
applied
motor kW
0.01A
standard
rating
1
1
0.01A
standard
rating
0.01%
standard
rating
0.01%
standard
rating
0.01Hz
0.00
0.01s
0.50
: Press the
or
V
The new data takes effect after the
pressed to store the data.
X : The data can be changed only while the
inverter is stopped.
4
X
0
X
4
X
6
0
X
12
0
X
0
X
6
4
4
4
4
key to change the data.
key is
FUNC
DATA
Selecting Functions

Hide quick links: