IMO VXSM75-1 Instruction Manual page 67

Imo jaguar vxsm general purpose inverter
Table of Contents

Advertisement

H40
Maximum temperature of heat sink
The maximum value in each hour is displayed
in degree C.
H41
Maximum effective current
The maximum value in each hour is displayed
in A.
H42
Main circuit capacitor life
The capacity of the capacitor in the main
circuit is displayed in %. For the measuring
conditions,
refer
"Measurement of capacitance of capacitor in
main circuit".
H43
Cooling fan operation time
Integral hours is displayed. The displayed
time is 0 to 6500, indicating 0 to 65000 hours.
(Though the displayed value is in ten hours,
the inverter adds each hour. Operation
shorter than one hour is not counted.)
H44
Inverter ROM version
The version of the software of the inverter is
displayed.
H45
Keypad panel ROM version
The version of the software of the keypad
panel is displayed.
H46
Option ROM version
For inverters with optional equipment, the
version of the optional software is displayed.
5-38
to
section
8-2
(1)
A: Alternative motor parameters
A01
Maximum frequency 2
The maximum frequency output by the inverter
for motor 2. This parameter functions in the
same way as F03 "Maximum output frequency
1". For the description, refer to F03 "Maximum
output frequency 1".
A02
Base frequency 2
The maximum output frequency in the constant
torque zone of motor 2, that is, the output
frequency at the rated output voltage. This
parameter functions in the same way as F04
"Base frequency 1". For the description, refer to
F04 "Base frequency 1".
A03
Rated
voltage
frequency 2)
The rated output voltage supplied to motor 2.
This parameter functions in the same way as
F04 "Rated voltage 1". For the description, refer
to F05 "Rated voltage 1".
A04
Maximum voltage 2 (at maximum
frequency 2)
The maximum output voltage of the inverter for
motor 2. This parameter functions in the same
way as F06 "Maximum voltage 1". For the
description, refer to F06 "Maximum voltage 1".
A05
Torque boost 2
The torque boost function of motor 2. This
parameter functions in the same way as F09
"Torque boost 1". For the description, refer to
F09 "Torque boost 1".
A06
Electronic thermal overload relay for
motor 2 (Select)
A07
Electronic thermal overload relay for
motor 2 (Level)
A08
Electronic thermal overload relay for
motor 2 (Thermal time constant)
The electronic thermal overload relay functions
of motor 2. These parameters function in the
same way as F10 through F12 Electronic
thermal overload relay for motor 1. For the
description, refer to F10 through F12.
A09
Torque vector control 2
The torque vector function of motor 2. This
parameter functions in the same way as F42
"Torque vector control 1". For the description,
refer to F42 "Torque vector control 1".
2
(at
base
Selecting Functions