H01
Total operation time
The total power-on time of the inverter is
displayed.
A number between 0 and 6500 is displayed,
indicating 0 to 65000 hours. (The time is
displayed in ten hours, though the inverter
counts each hour. The time shorter than one
hour is not counted.)
H02
Trip history
A history of the latest four events of activation
of protective functions is stored in
memory. To call up each event, press the
key. Press the
or
V
history.
Procedure
Dislay
example
1
Call up
H
0
H
0
2
2
1.
O
U
FUNC
DATA
3
2.
O
H
V
4
3
O
C
V
5
4.
-
-
V
6
e
n
The new record of protective operation is stored
in the latest protective operation memory, and
the previous records are shifted one by one, and
the record of protective operation before the
four previous ones is deleted.
H03
Data initializing (Data reset)
This function restores (initializes) the factory
data over alterations made by the user.
Setting 0: Disabled
1: Initialize
Press the
and
STOP
change the setting to "1", then press the
to initialize the settings of all functions. After
5-30
I
V
key to confirm the
Remarks
2
The latest
2

protective operation

is displayed.
The protective
1
operation before
the previous one is
displayed.
The protective
1
operation before
the two previous
ones is displayed.
The protective
-
operation before
the three previous
ones is displayed.
d
keys simultaneously to
key
FUNC
DATA
initialization
is
completed,
automatically returns to "0".
H04
Auto-reset (Times)
H05
Auto-reset (Reset interval)
When the protective function of the inverter
which starts the retry function is activated,
operation of the inverter protective function is
canceled to restart the inverter automatically
instead of an alarm and output stop.
H04
Set the number of resetting cycles of the
protective function.
Setting range: 0 to 10 (0: retry inactive)
H05
Set the wait time from activation of a
protective function to resetting.
Setting range: 2 to 20 s
Inverter protective functions for retry and start
OC1, OC2, OC3
Overcurrent
OU1, OU2, OU3
Overvoltage
OH1
Overheated heat sink
dbH
Overheated braking resistor
OL1
Overloaded motor 1
OL2
Overloaded motor 2
OLU
Overloaded inverter
When the data of H04 Retry (Times) is set to
1 to 10, retry operation starts and the time set
at H05 "Retry (Reset interval)" elapses, then
an inverter start command is automatically
input. If the cause of the alarm has been
removed, the inverter starts without entering
the alarm mode. If the cause of the alarm
remains, the protective function is activated
again to wait for the time set at H05 "Retry
(Times)". If the cause of the alarm is not
removed after the number of repetition cycles
set at H04 "Retry (Reset interval)", the
inverter enters the alarm mode.
WARNING
If the retry function has been
selected, the inverter may automatically
restart according to some causes after
tripping. (Design the machine so that human
safety is ensured after restarting.)
Otherwise an accident could occur.
the