Functions for short frame
Function
Frequency command
Frequency command
Operation command
Reset command
Calculated torque
value monitor
Torque current
monitor
Output frequency
monitor
Operation state
monitor
Table 9-4-7 Short frame
(4)
Alarm display data
The failure description (alarm description) is as
shown in the table below. The failure code is in
the hexadecimal notation.
Failure
Description
code
0000
No alarm
0001
Overcurrent, during
acceleration
0002
Overcurrent, during
deceleration
0003
Overcurrent, during
constant speed
operation
0006
Overvoltage, during
acceleration
0007
Overvoltage, during
deceleration
0008
Overvoltage, during
constant speed
operation
000A
Undervoltage
000B
Input phase loss
0011
Heat sink overheat
Table 9-4-8 Failure description
9-23
Command
Data direction
type
character
a
Selecting
e
Selecting
f
Selecting
m
Selecting
h
Polling
I
Polling
j
Polling
k
Polling
Indication
on panel
---
OC1
OC2
OC3
OU1
OU2
OU3
LU
Lin
OH1
Data range; transmission
data / actual data
Same as S01
Same as S05
Same as S06
4 spaces
Same as M07
Same as M08
Same as M09; no sign .
is attached
Same as M14
Failure
Description
code
0012
External alarm
0016
Braking resistor
overheat
0017
Motor 1 overload,
0018
Motor 2 overload,
0019
Inverter overload
001F
Memory error
0020
Keypad panel
communication error
0021
CPU error
0025
Output phase loss error
loss error
0026
RS485 communication
error
Change
during
operation
-
-
-
-
-
-
-
-
Indication
on panel
OH2
dbH
OL1
OL2
OLU
Er1
Er2
Er3
Er7
Er8
Specifications