1-4

Transportation

Always hold the main unit when carrying the
inverter.
If covers or parts are held, the inverter may be
broken or it may drop.
1-5

Storage

To store temporarily
Store the inverter in an environment described
in Table 1-5-1.
Table 1-5-1 Storage environment
Item
Specifications
Ambient
-10~+50
temperature
degree C
Storage
(Note 1)
-25~+65
temperature
degree C
Relative
5~95%
humidity
(Note 2)
Atmosphere
The product must not be exposed
to dust, direct sunlight, corrosive
or flammable gases, oil mist,
vapor, water drops or vibration.
There must be little salt in the
atmosphere.
Atmospheric
86~106kPa
pressure
(During storage)
70~106kPa
(During transportation)
Note 1: The storage temperature is for a short
time during transportation or the like.
Note 2: Even if the humidity is within the
requirements of the specifications,
places
with
changes are subject to condensation
or freezing. Avoid storing the inverter
in such places.
(1)
Do not place the inverter directly on
the floor.
(2)
If the ambient atmosphere is adverse,
wrap the inverter in a vinyl sheet or the
like when storing.
(3)
If humidity may give an ill effect, add a
drying agent (such as silica gel) in the
package prepared as described in
item (2).
Before Using the Inverter
Places not subjected
to abrupt
temperature changes
or condensation or
freezing
abrupt
temperature
To store for a long time
The long-term storage method of the inverter
varies largely according to the environment of
the storage site. General storage methods are
described below.
(1) The
storage
site
requirements
of
temporary storage. However, for storage
exceeding three months, the upper limit of
the ambient temperature shall not exceed
30 °C. This is for the prevention of
deterioration of electrolytic capacitors left
turned off.
(2) The package must be air tight so that
moisture will not enter. Add a drying agent
inside the package to contain the relative
humidity inside the package within 70%.
(3) The inverter installed on a unit or control
panel and left is likely to be exposed to
moisture and dust. If this is the case,
remove the inverter and move it to a
preferable environment.
(4) Electrolytic capacitors left turned off for an
extended period of time deteriorate. Do not
store for one year or more without turning
the power on.
must
satisfy
the
specifications
for
1-6