2-3-4 Terminal Layout

(1) Main circuit terminal block
Inverter type
VXSM40-1
VXSM75-1
VXSM40-3
VXSM75-3
VXSM50-3
VXSM220-3
VXSM150-1
VXSM220-1
VXSM400-3
2-9
Main circuit terminal drawing
DB
P1 P(+) N(-)
L1/L
L2/N
U
G
DB
P1 P(+) N(-)
G
L1/L
L2/N
DB
P1 P(+) N(-)
G
L1/R L2/S L3/T
L1/L
L3/N DB
G
L1/R L2/S L3/T DB
G
V
W
G
Screw size : M3.5
Tightening torque : 1.2N . m
U
V
W
Screw size : M4
Tightening torque : 1.8N . m
U
V
W
Screw size : M4
Tightening torque : 1.8N . m
P1 P(+) N(-)
Screw size : M4
Tightening torque : 1.8N . m
P1 P(+) N(-)
Screw size : M4
Tightening torque : 1.8N . m
Installation and Connection
G
G
U
V
W
G
U
V
W