Install Slide Racks; Install The Free Air Vented Drain Lines - Cleveland steamcraft 21-CET-8 Service Manual

Counter type convection steamer
Hide thumbs Also See for steamcraft 21-CET-8:
Table of Contents

Advertisement

Page 14
Model 21 -CET-8 Service Manual
Figure 2-12. Slide Rack Installation
Install the Free Air Vented
Drain Lines
5. After the steamer and stand have been positioned and leveled, install the
slide racks in the steamer as explained below.

Install Slide Racks

1. Refer to Figure 2-12. Each rack has four loops: two at the top and two at
the bottom. Hold the slide rack so the ends of the hanger loops point
down, as shown in the figure
2. Slide one rack into the compartment with loops toward one side.
3. Hook the loops over the top and bottom pins.
4. Repeat steps 1 through 3 for the other rack.
DEATH, INJURY, AND EQUIPMENT DAMAGE could
result from improper installation of the drain outlet lines.
Improper installation of these lines could void the
SteamCraft3.1 warranty. The following restrictions are critical
to the safety of personnel and equipment, and must not be
violated under any circumstances.
Do not connect the drain line into PVC pipe, or any other
drain material that cannot sustain 180° F.
Do not connect drains from any other equipment to the
SteamCraft 3.1 drain line.
Do not connect the drain outlet extension line directly to a
floor drain or sewer line.
Furnishing and installing the drain line is the responsibility of the owner
and/or installer. Figure 2-13 illustrates a drain layout recommended by
Cleveland Range. Observe the following instructions to determine the pipe
size, the number of fittings required, and the layout of the drain line.
.
WARNING
Printed 12/90