f.
Install the threaded end of the Vent stack into the ½" outlet of the drain tee using pipe sealant.
g. The unit is now ready for connection to a drain, see Chapter 4, Section B, Part 9.
Figure 4-11 Slide
Rack Installation

9. Install the Free Air Vented Drain Lines

Furnishing and installing the drain line is the responsibility of the owner and/or installer. Figure 4-13
illustrates a drain layout recommended by Cleveland Range.
DEATH, INJURY, AND EQUIPMENT DAMAGE could result from improper installation of the
drain outlet lines.
Improper installation of these lines could void the SteamChef
following restrictions are critical to the safety of personnel and equipment, and must not be violated
under any circumstances.
Do not connect the drain line into PVC or any drain material that cannot sustain 180
Do not connect drains from any other equipment to the drain line of the SteamChef 3 Steamer.
Do not connect the drain outlet extension line directly to a floor drain or sewer line.
The drain line must be free air vented, have gravity flow from the steamer, and terminate outside
the perimeter of the unit.
a. The drain lines must be installed in compliance with the Basic Plumbing Code of the Building
Officials and Code Administrators International, Inc. (BOCA), and the Food Service Sanitation
Manual of the Food and Drug Administration (FDA) and any state, provincial or local codes.
b. Do not install the steamer directly over a drain. Steam rising up out of the floor drain will
adversely affect operation, cooling air ventilation and may damage electrical components. (See
Figure 4-13)
c. The total length of pipe and number of bend fittings required to reach the open drain determines
the pipe size used to extend the drain line to an open drain.
If the drain outlet extension requires 6 feet or less of pipe, and no more than two elbows are
required, 1inch (or larger) pipe and fittings are acceptable.
If the drain outlet extension requires 6 to 12 feet of pipe, or requires three or more elbows, or is
installed on a Cleveland Range Model ES222824S stacked stand, 2 -inch (or larger) pipe and
fittings are required.
d. The drain line must have a gravity flow from the steamer drain outlet to the floor drain. Do not install
a trap in the drain line.
VENT STACK
DRAIN TEE
Figure 4-12 Steam Vent
Assembly Installation
WARNING
27
3 Steamers warranty. The
o
F.