2-4. Auto adjustment

Please click the "Exit" button on the Video / Frequency Adj. screen after completing the
The message "Adjustment Starts. Shoot White Chart." is displayed on the Camera Adjustment screen. The
auto adjustment starts when the "Execute" button is clicked on the Camera Adjustment screen.
< Adjustment procedure >
1. Set the lens iris to "AUTO".
2. Aim the Camera-Recorder at white chart under the Halogen lamp condition (3100K, 2000Lux).
3. Shoot the white chart so that the full screen is white.
4. Clicking "Execute" button, the following adjustments are executed automatically.
● Blemish Compensation Adjustment
● SUB Level Adjustment
● White Shading Adjustment (1)
5. When the White Shading Adjustment (1) adjustment is completed, the "Execute" button is become effective on
the Camera Adjustment screen and the following screen is displayed.
6. Aim the Camera-Recorder at grayscale chart under the Halogen lamp condition (3100K, 2000Lux).
NOTE: Shoot the white portion at center of grayscale chart greatly.
7. Clicking "Execute" button, the "Standard Sensitivity Adjustment" is executed automatically.
ELE-9