Features and Specifications
2.5-15 V signal or TTL-compatible input,
selectable logic. TTL input impedance: 2 k (in
series with one diode drop).
Voltage and current programming inputs
(source must be isolated):
0-5 k, 0-10 k resistances;
0-5 V, 0-10 V (default) voltage sources.
Input impedance (V and I): approximately
100 k.
Output voltage and current: 0-5 V, 0-10 V
(default);
Output impedance (V and I): approximately
221 Ω.
Output short circuit current: approximately
50 mA.
1% zero to full scale output for the default
range.
5 V/line (Line drop is subtracted from total voltage
available at supply output.)
0-5 V (ISOL interface);
input impedance: approx. 200 k;
output impedance: low
RS-232, GPIB interfaces