Power Requirements Table
The following table describes the power specifications for the GoQAM.
Item
Supply Voltage
Fuses
Line Frequency
Power Required
Power Dissipated
In Rush Current
Rack Requirements Table
Item
Rack Mount Type
Height
Width
Depth
Weight
150
Specification
90V to 130V AC @ 47 to 63 Hz (AC unit)
180V to 264V AC @ 47 to 63 Hz (AC unit)
–42V to –57V DC (DC unit)
4.0 A SLO BLO 250V (AC unit)
6.3 A SLO BLO 250V (DC unit)
47 to 63 Hz (AC unit only)
RF GoQAM: 155 VA (typical)
IF GoQAM: 85 VA (typical)
RF GoQAM: 151 Watts (typical)
IF GoQAM: 80 Watts (typical)
35 amps maximum, Vin = 130V AC (AC unit)
75 amps maximum, Vin = 264V AC (AC unit)
15 amps maximum, Vin = -57V DC (DC unit)
Specification
EIA RS-310
1.75 in./44.45 mm
19 in./482.6 mm
22.5 in./571.5 mm
13.5 lb./5.4 kg