System Settings - Usb Tab - AMX NXD-430 Operation/Reference Manual

4.3" modero wall/flush mount touch panels
Hide thumbs Also See for NXD-430:
Table of Contents

Advertisement

System Settings Page - Master Tab (Cont.)
Mode:
System Number:
Master IP/URL:
Master Port Number:
Username/Password:
NDP Name:
Back:

System Settings - USB Tab

FIG. 60
System Settings Page - USB Tab
System Settings Page - USB Tab
Connection Status icon: Shows the current state of the panel's connection to the Master (green = online, red =
DHCP/Static
IP Address
Back:
NXD-430/NXD-435 4.3" Wall/Flush Mount Touch Panels
Cycles between the different connection modes (URL, Listen, and Auto)
(ETHERNET Only - disabled when USB is selected)
• URL - In this mode, enter the IP/URL, Master Port Number, and username/
password (if used) on the Master.
The System Number field is read-only because the panel obtains this information
from the communicating Master.
• Listen - In this mode, add the Modero panel address into the URL List in NetLinx
Studio and set the connection mode to Listen. This mode allows the Modero touch
panel to "listen" for the Master's communication signals.
The System Number and Master IP/URL fields are red-only.
• Auto - In this mode, enter the System Number and a username/password (if
applicable). This mode is used when both the panel and the NetLinx Master are on
the same Subnet and the Master has its UDP feature enabled.
Master IP/URL field is read-only.
Allows you to enter a system number. Default value is 0 (zero).
(ETHERNET Only - disabled when USB is selected)
Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only - disabled when USB is selected)
Enters the port number used with the NetLinx Master.
• Default value is 1319. (ETHERNET Only - disabled when USB is selected)
If the target Master has been previously secured, enter the alphanumeric string (into
each field) assigned to a pre-configured user profile on the Master.
This profile should have the pre-defined level of access/configuration rights.
The Nexus Delivery Protocol name for the device. The NDP name allows use of a
master web interface, NetLinx Studio 2.4 or commands to bind the device with
NetLinx masters.
Saves any changes and returns to the previously active touch panel page.
offline). See the Connection Status Icon section on page 46 for details.
Switches between HDHCP and Static connections.
The IP address of the device
Saves any changes and returns to the previously active touch panel page.
Setup Pages and Descriptions