AMX NXD-430 Operation/Reference Manual page 30

4.3" modero wall/flush mount touch panels
Hide thumbs Also See for NXD-430:
Table of Contents

Advertisement

Panel Calibration
FIG. 16
Touch Panel Calibration Screens
3.
After the "Calibration Successful." message appears, press anywhere on the screen to continue and
return to the Setup page.
If the calibration was improperly set and you cannot return to the Calibration
page through the panel's Setup Pages or by pressing the Front Setup Access
button, this firmware page may be accessed via G4 WebControl. Here, you can
navigate to the Protected Setup page and press the Calibrate button through a VNC
window.
This action causes the panel to go to the Calibration page seen above, where the
actual touch panel may be physically calibrated again using the above procedures.
20
On-screen crosshairs used for
calibration of the touch device
The request to touch the crosshairs
is the first on-screen message
Calibration successful is the second
on-screen message that appears
after the calibration process is
completed
NXD-430/NXD-435 4.3" Wall/Flush Mount Touch Panels