Installing The Nxd-430 And Nxd-435 Into Drywall - AMX NXD-430 Operation/Reference Manual

4.3" modero wall/flush mount touch panels
Hide thumbs Also See for NXD-430:
Table of Contents

Advertisement

9.
Place the faceplate back onto the main device.
10.
Reconnect the terminal Ethernet and USB to their respective locations on the Ethernet port and NetLinx
Master.

Installing the NXD-430 and NXD-435 into Drywall

The NXD-430 and NXD-435 come with a clear plastic backbox (FIG. 8) designed to attach the panel to
standard drywall. This backbox has a locking tab on three of the four faces (missing only on the face
containing the space for the connections) to help lock the backbox to the wall. These locking tabs are only
extended AFTER the backbox is inserted into the wall.
FIG. 8
NXD-430 backbox with closed and open locking tabs
When installing the backbox, make absolutely sure that the assembly is in the correct
position and in the correct place. Once the locking tabs are extended and locked into
place, removing the backbox is possible, but it will be very difficult without having
access to the back of the wall itself or damaging the wall.


1.
Prepare the area by removing any screws or nails from the drywall before beginning the cutout process.
2.
Cut out the surface for the back box. Refer to the dimensions in FIG. 9 for more information.
NXD-430/NXD-435 4.3" Wall/Flush Mount Touch Panels
Locking tab screws
Locking tabs - Closed
Refer to the diagram for detailed installation dimensions as shown in FIG. 9.
Cutting out the surface slightly smaller than what is outlined in the installation drawings, in order to
make any necessary cutout adjustments, is highly recommended.
Installation
Locking tabs - Open
11