Installing The Nxd-430 Panel Within A Rough-In Box - AMX NXD-430 Operation/Reference Manual

4.3" modero wall/flush mount touch panels
Hide thumbs Also See for NXD-430:
Table of Contents

Advertisement

Stud Mounting tabs
FIG. 6
CB-TP5i Rough-In Box components
3.
Remove the appropriate wiring knockouts from the rough-in box (FIG. 6) to accommodate the cables
being threaded through to the touch panel.
4.
Thread the incoming Ethernet and USB wiring through the knockouts. Use of the left wiring knockouts
are recommended with this installation. Leave enough slack in the wiring to accommodate any re-
positioning of the panel.
5.
Install the drywall/sheetrock before inserting the device into the CB-TP5i.

Installing the NXD-430 panel within a Rough-In Box

The Rough-In Box must be mounted prior to continuing this section. Refer to the procedures in the
Pre-Wall Installation of the Rough-In Box section on page 8 for detailed pre-wall installation instructions.
Verify that all necessary cables have been threaded through the knockouts on the left
of the Rough-In Box and the connections have been tested prior to installation of the
NXD-430.
1.
Remove the faceplate from the main NXD-430 unit by gripping the faceplate from the top and lifting up
and then pulling with gentle outward force.
2.
Disconnect the capacitive touch connector from the 10-pin plug on the faceplate.
NXD-430/NXD-435 4.3" Wall/Flush Mount Touch Panels
Stud
Wiring knockouts
Installation
9