AMX NXD-430 Operation/Reference Manual page 20

4.3" modero wall/flush mount touch panels
Hide thumbs Also See for NXD-430:
Table of Contents

Advertisement

Installation
Screws for mounting
Back Box to touch panel
FIG. 7
NXD-430 panel installation into a CB-TP5i (pre-wall construction)
Be sure to pull the faceplate UP before pulling it out and away from the rest of the
device. Pulling straight outward may lead to damage to the faceplate, including
breaking off the tabs that attach the faceplate to the device and damaging the
capacitive touch 10-pin female connector.
3.
Thread the incoming Ethernet and USB wiring from their terminal locations through the surface opening.
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
4.
Push the back box into the wall opening. Ensure that the locking tabs lie flush against the back box.
5.
Connect both connectors to their corresponding locations along the left side of the touch panel.
6.
Test the incoming wiring by attaching the panel connections to their terminal locations and applying
power via the PoE Injector. Verify that the panel is receiving power and functioning properly to prevent
repetition of the installation.Test the incoming wiring by connecting the panel connections to their
terminal locations and applying power via the PoE Injector. Verify that the panel is receiving power and
functioning properly to prevent repetition of the installation.
Do not disconnect the connectors from the touch panel. The unit must be installed
with the attached connectors before being inserted into the Rough-In Box.
7.
Extend the locking tabs on the sides of the back box by tightening the screws inside the box. Not all of the
tabs must be extended to lock the back box in place, but extending a minimum of the top and bottom tabs
is highly recommended. Apply enough pressure to the screw head to keep the box flush with the wall: this
ensures that the locking tabs will tighten up against the inside of the wall.
The back box is clear to allow visual confirmation that the tabs have been extended and are gripping the
wall. This also allows visual confirmation that the tabs have been retracted away from the wall if the
entire assembly has to be removed from the wall for any reason.
The maximum recommended torque to screw in the locking tabs on the back box is 5
IN-LB [56 N-CM]. Applying excessive torque while tightening the locking tab screws,
such as with powered screwdrivers, can strip out the tabs or damage the back box.
8.
Attach the capacitive touch connector to the10-pin plug on the faceplate.