Master Connection Tab - NetLinx Master Ethernet IP Address - URL Mode

In this mode, enter the System Number (zero for an unknown System Number) and the IP/URL of the Master
(Master Port Number is defaulted to 1319).
1.
Open the System Settings page - Master tab (see FIG. 35 on page 34).
2.
Press the Type button until the choice cycles to Ethernet. Refer to the System Settings Page section on
page 55 for more information about the fields on this page.
3.
Press the Mode button until the choice cycles to URL.
By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this value
directly from the communicating target Master, virtual or not. A Virtual Master system value can be set
within the active AMX software applications such as NetLinx Studio, TPD4, or IREdit.
If the panel does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number from
within the Device Addressing dialog is correctly assigned.
4.
Press the Master IP/URL button to open a keyboard and enter the Master IP Address obtained from the
Diagnostics - Networking Address dialog (in NetLinx Studio), and press Done.
Do not alter the Master Port Number value. This is the default value used by NetLinx.
5.
Enter a Username and Password (into their respective fields) if the target Master has been previously
secured.
6.
Press the Back button to open the Protected Setup page.
7.
Press the Reboot button to save changes and restart the panel.

Master Connection Tab - NetLinx Master Ethernet IP Address - Listen Mode

In this mode, add the Modero panel IP Address into the URL List of the Master by using NetLinx Studio. This
mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from its URL list).
1.
Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP Address
from the IP Settings field of the System Connection page.




2.
Toggle the Type button until Ethernet is selected.
3.
Press the Mode button until the choice cycles to Listen. The System Number and Master IP/URL fields
are then disabled.
4.
Enter a Username and Password into their respective fields if the target Master has been previously
secured.
5.
In NetLinx Studio, select the OnLine Tree tab in the Workspace window.
6.
Enter the System and Device number for the specific Master associated with the touch panel as seen in
the OnLine Tree tab.
7.
In NetLinx Studio, select Diagnostics > URL Listing to open the URL Listing dialog.
8.
Click Add and enter the IP Address of the touch panel in the Add URL dialog.
9.
Click OK to enter the IP Address and add it to the list.
10.
Click Done when finished adding your panel information to the list.
11.
Press the Reboot button to save changes and restart the panel.
NXD-430/NXD-435 4.3" Wall/Flush Mount Touch Panels
The DHCP/Static field, in the IP tab of the System Settings page, must be set to DHCP to get
Dynamic IP information for the panel.
Press the Reboot button on the Protected Setup page to save changes and restart the panel.
After power-up, press the front button for 6 seconds to access the Status page.
Navigate to the Setup > Protected Setup > System Settings page, click the IP Settings tab, and
note the newly obtained Dynamic IP Address information. This information is then entered into the
URL List for the connected NetLinx Master.
Configuring Communication
35