Configuring Communication
10.
Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The default System
value is one.
11.
Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list.
12.
Power-up your panel and press and hold the grey Front Setup Access button (for 3 seconds) to continue with the
setup process and proceed to the Setup page.
13.
Select Protected Setup > System Settings (located on the lower-left) to open the System Settings page (FIG. 65).
FIG. 65
Sample System Settings page (for Virtual Master communication)
14.
Press the blue Type field (from the Master Connection section) until the choice cycles to the word Ethernet.
ICSNet communication cannot be used on either 1200V-Series or VG-Series panels.
15.
Press the Mode field until the choice cycles to the word URL.

16.
Press the Master IP/URL field to open a Keyboard and enter the IP Address of the PC used as the Virtual Master.
17.
Click Done to accept the new value and return to the System Settings page.
18.
Do not alter the Master Port Number value (this is the default value used by NetLinx).
19.
Press the Back button to open the Protected Setup page.
20.
Press the on-screen Reboot button to both save any changes and restart the panel.

Master Connection section - NetLinx Master Ethernet IP Address - URL Mode

In this mode, enter the System Number (zero for an unknown System Number) and the IP/URL of the Master (Master
Port Number is defaulted to 1319).
1.
Press the blue Type field (from the Master Connection section) until the choice cycles to the word Ethernet. Refer
to the System Settings Page section on page 102 for more information about the fields on this page.
2.
Press the Mode field until the choice cycles to the word URL.
By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this value directly
from the communicating target Master (virtual or not). A Virtual Master system value can be set within the active
AMX software applications such as: NetLinx Studio, TPD4, or IREdit.
If the panel does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number (from
within the Device Addressing dialog) is correctly assigned.
3.
Press the Master IP/URL field to open a Keyboard and enter the Master IP Address (obtained from the
Diagnostics - Networking Address dialog of the NetLinx Studio application).
4.
Click Done to accept the new value and return to the System Settings page.
5.
Do not alter the Master Port Number value (this is the default value used by NetLinx).
6.
Enter a username and password (into their respective fields) if the target Master has been previously secured.
62
By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this value
directly from the communicating target Master (virtual or not). A Virtual Master system value can be set
within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit.
The System Number is
assigned to the Master
within the AMX
software application
(these must match)
Enter the IP Address
information of the PC
used as a Virtual
Master
When using a Virtual Master,
there is no need to enter a
username and/or password
NXD/T-1200V Wall/Flush Mount Touch Panel