FIG. 85
Sample System Settings page (for Virtual Master communication)
14.
Press the blue Type field (from the Master Connection section) until the choice cycles to the word
Ethernet. ICSNet communication cannot be used on either 1200V-Series or VG-Series panels.
15.
Press the Mode field until the choice cycles to the word URL.

16.
Press the Master IP/URL field to open a Keyboard and enter the IP Address of the PC used as the Virtual
Master.
17.
Click Done to accept the new value and return to the System Settings page.
18.
Do not alter the Master Port Number value (this is the default value used by NetLinx).
19.
Press the Back button to open the Protected Setup page.
20.
Press the on-screen Reboot button to both save any changes and restart the panel.

Master Connection section - NetLinx Master Ethernet IP Address - URL Mode

In this mode, enter the System Number (zero for an unknown System Number) and the IP/URL of the Master
(Master Port Number is defaulted to 1319).
1.
Press the blue Type field (from the Master Connection section) until the choice cycles to the word
Ethernet. Refer to the System Settings Page section on page 147 for more information about the fields on
this page.
2.
Press the Mode field until the choice cycles to the word URL.
By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this value
directly from the communicating target Master (virtual or not). A Virtual Master system value can be set
within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit.
If the panel does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number (from
within the Device Addressing dialog) is correctly assigned.
3.
Press the Master IP/URL field to open a Keyboard and enter the Master IP Address (obtained from the
Diagnostics - Networking Address dialog of the NetLinx Studio application).
4.
Click Done to accept the new value and return to the System Settings page.
5.
Do not alter the Master Port Number value (this is the default value used by NetLinx).
6.
Enter a username and password (into their respective fields) if the target Master has been previously
secured.
7.
Press the Back button to open the Protected Setup page.
8.
Press the on-screen Reboot button to both save any changes and restart the panel.
VG-Series Modero Touch Panels
By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this
value directly from the communicating target Master (virtual or not). A Virtual Master system
value can be set within the active AMX software applications such as: NetLinx Studio, TPD4, or
IREdit.
Configuring Communication
The System Number is
assigned to the Master
within the AMX
software application
(these must match)
Enter the IP Address
information of the PC
used as a Virtual
Master
When using a Virtual Master,
there is no need to enter a
username and/or password
103